Summary of Contents for Honda Civic 1990 VTEC Service Manual - Page 18

  • Honda Civic 1990 VTEC Service Manual - Page 18

    Preparation of Work — Electrical - Before making any repairs on electric wires or pans, disconnect the battery cables item the hat- tery starting with the negative (—l terminal. f / - After making repairs. check each wire or pan lar proper routing and installation. Also check to see that they are connected properly. - Always connect the battery positive (+1 cable first. then connect the negative l—l cable. - Coat the terminals with clean grease after connect~ Ing the battery cables. - Don‘t ierget to install the terminal cover over the positive battery terminal alter connecting. - Belore installing a new iuse. isolate the cause and take corrective measures. particularly when fre- quent iuse lailure occurs. - Be sure to install the terminal cover over the can» neclions after a wire or wire harness has been cor» nected. . - TERMINAL COVER - As to locking connectors. be sure to disengage the lock before disconnecting. - Conventional connectors may be of two types, those in which the lock is pressed to remove, and those in which the lock is pulled up to remove. Be sure to ascertain the type 01 locking device before beginning work. The following is a depiction of the means of disconnecting various typical connectors. Press to disengage: fiKk &$&r Pull up to dlsengege: 1-12 ‘V