A/C Receiver/Dryer Desiccant Replacement

1.Remove the condenser.

2.Remove the cap (A) from the bottom of the condenser, then remove the O-rings (B), the filter (C) and the desiccant (D).

 

3.Install the desiccant in the reverse order of removal, and note these items:

  • Replace the O-rings with new ones, and apply a thin coat of refrigerant oil (KEIHIN SP-10) before installing them.