Recirculation Control Motor Replacement

NOTE: LHD type is shown, RHD type is symmetrical.

1.Remove the ECM/PCM.

2.Remove the bolt and the bracket (A). Disconnect the 7P connector (B) and the harness clip (C) from the recirculation control motor (D). Remove the self-tapping screws and the recirculation control motor from the blower unit.

 

3.Install the motor in the reverse order of removal. After installation, make sure the motor runs smoothly.