Door Lock Actuator Test

Driver's Door without Super Locking:


1.Remove the driver's door panel.

2.Disconnect the 2P connector (A) from the actuator.

 


3.Check actuator operation by connecting power and ground according to the table. To prevent damage to the actuator, apply battery voltage only momentarily.

 

4.If the actuator does not work as specified, replace it.

Driver's Door with Super Locking:


1.Remove the driver's door panel.

2.Disconnect the 6P connector (A) from the actuator.

 


3.Check actuator operation by connecting power and ground according to the table. To prevent damage to the actuator, apply battery voltage only momentarily.

 

4.If the actuator does not work as specified, replace it.

Passenger's Door without Super Locking:


1.Remove the passenger's door panel.

2.Disconnect the 2P connector (A) from the actuator.

 

3.Check actuator operation by connecting power and ground according to the table. To prevent damage to the actuator, apply battery voltage only momentarily.

 

4.If the actuator does not work as specified, replace it.

Passenger's Door with Super Locking:


1.Remove the passenger's door panel.

2.Disconnect the 6P connector (A) from the actuator.

 

3.Check actuator operation by connecting power and ground according to the table. To prevent damage to the actuator, apply battery voltage only momentarily.

 

4.If the actuator does not work as specified, replace it.