Door Lock Knob Switch Test - With Super Locking

Driver's Door (With Supre Locking System):


1.Remove the driver's door panel.

2.Disconnect the 6P connector (A) from the super locking actuator.

 

3.Check for continuity between the terminals.

  • There should be continuity between the No. 3 and No. 4 terminals when the door lock knob switch is LOCK position.
  • There should be continuity between the No. 1 and No. 4 terminals when the door lock knob switch is UNLOCK position.

4.If the continuity is not as specified, replace the super locking actuator.

Passenger's Door (With Supre Locking System):


1.Remove the passenger's door panel.

2.Disconnect the 6P connector (A) from the super locking actuator.

 

3.Check for continuity between the terminals.

  • There should be continuity between the No. 1 and No. 4 terminals when the door lock knob switch is UNLOCK position.

4.If the continuity is not as specified, replace the super locking actuator.