Stop the engine and open the rear door [Figure 70-70-9].
Disconnect the connector (Item 1) [Figure 70-70-9] from the fuel shut-off solenoid.
Use an ohmmeter to check the fuel shut-off solenoid.
The reading between Red to Black must be between 10.5 and 11 ohms [Figure 70-70-10].
The reading between White to Black must be between.4-.5 ohms.
Reconnect connector (Item 1) [Figure 70-70-9].