Remove the actuator (Item 1) [Figure 20-41-67] from the control valve. (See Lift Spool Removal And Installation on Page 20-41-22.)
Remove the screws (Item 1) [Figure 20-41-68] from the cap.
Installation: Tighten the bolt to 90-100 in.-lbs. (10,2-11,3 Nm) torque.
Remove the spool assembly (Item 1)[Figure 20-41-69] and seal from the control valve.
Assembly: Always use a new spool seal and new O-rings.