BOBCAT S130 – HYDROSTATIC MOTOR CARRIER (SJC) – Shaft Seal Removal And Installation

The tool listed is necessary for the following procedure:
MEL1420 – Carrier Seal Tool

Remove the hydrostatic motor. (See Removal And Installation on Page 30-20-1.)

The motor carrier seal (Item 1) [Figure 30-30-1] is located on the outside of the motor carrier shaft.

Drill a 0.125 in. (3 mm) hole in the motor carrier seal [Figure 30-31-2].

Use a slide hammer to remove the seal from the motor carrier shaft [Figure 30-31-3].

Installation: Install a new seal over the motor carrier shaft [Figure 30-31-4].

Installation: Install MEL1420 Carrier Seal Tool over the carrier seal [Figure 30-31-5].

Hit the tool with a hammer until the seal is fully seated on the carrier shaft [Figure 30-31-5].

Photo [Figure 30-31-6] shows the motor carrier seal correctly installed.

Inspect the O-ring (Item 1) [Figure 30-31-6] and replace if needed.

NOTE: Before reinstalling the hydrostatic motor, check the plug (Item 2) [Figure 30-31-6] located in the center of the carrier shaft for tightness. If the plug becomes loosened, case drain lubrication oil from the hydrostatic motor can leak into the chaincase.