If the pressure is not correct, adjust the main relief valve.
Remove the end cap (Item 1) [Figure 20-30-5].
Turn the adjusting screw in or out until the pressure is correct.
NOTE: If the correct pressure can not be reached, replace the main relief valve. Check the pressure setting of the new relief valve.