If it is necessary to use a booster battery to start the engine, BE CAREFUL! There must be one person in the operator’s seat and…
The battery cables must be clean and the connections tight. Remove acid or corrosion from the battery and cables with a sodium bicarbonate (baking soda)…
Open the rear door. Disconnect the negative (-) battery cable (Item 1) [Figure 60-20-1]. Remove the battery hold down clamp (Item 2) [Figure 60-20-1]. Disconnect…
Use an Ohm meter to measure coil resistance [Figure 60-10-7]. Coil wires do not have polarity. Correct resistance for the auxiliary, lift and tilt lock…
Remove the cover to check or replace the relays. The location is shown in [Figure 60-10-5 on Page 5] & [Figure 60-10-6].
Remove the cover to check or replace the fuses.
The Loader has a 12 volt, negative ground alternator charging system. The electrical system is protected by a 100 amp master fuse (Item 1) [Figure…
The following troubleshooting chart is provided for assistance in locating and correcting problems which are most common. Many of the recommended procedures must be done…
To replace the rubber boot (Item 1) [Figure 50-114-25] on the control panel, remove the control lever. (See Control Lever Removal and Installation on Page…
Disconnect the electrical connectors (Item 1) [Figure 50-114-21] from the control lever switch handle. Remove the electrical connectors from the control lever switch handle. (See…