Raise the lift arms and install an approved lift arm support device. (See Installing Lift Arm Support Device on Page 10-20-1.) Lift and block the…
Author: Jack
The functions of the replenishing valves are: 1. To give replacement fluid to the low pressure side of the hydrostatic circuit. Replacement fluid is needed…
Remove the male coupler (Item 1) [Figure 20-121-2] & [Figure 20-121-3]. Installation: Tighten the male coupler (Item 1) [Figure 20-121-2] & [Figure 20-121-3] to 59…
Disconnect the auxiliary tubelines (Item 1) and drain tubeline (Item 2) [Figure 20-121-1] from the coupler block. Remove the two mounting bolts (Item 3) [Figure…
Inspect cartridges, check valves, solenoid valves and sealing washers for contamination or damage. Wash all parts in clean solvent. Use air pressure for drying them.…
Use a test meter to measure coil resistance [Figure 20-120-9]. Coil wires do not have polarity. Correct resistance is 11 ยฑ 1 ohms. Replace the…
Loosen the electrical brake solenoid nut (Item 1) [Figure 20-120-4]. Assembly: Tighten the solenoid nut to 15-45 in.-lbs. (1,7-5,1 Nm) torque. Remove the solenoid nut…
Raise the lift arms and install an approved lift arm support device. (See Installing Lift Arm Support Device on Page 10-20-1.) Raise the operator cab.…
Clean the block (Item 1) [Figure 20-110-6] to remove dirt before disassembly. Block ports are labeled for correct assembly. Remove the plug (Item 2) [Figure…
Lift and block the loader. (See LIFTING AND BLOCKING THE LOADER on Page 10-10-1.) Raise the lift arms and install an approved lift arm support…