Remove the BICS valve assembly from the control valve. (See BICSTM Valve, Removal And Installation on Page 20-41-9.) Remove the restrictor (Item 1) [Figure 20-41-49]…
Author: Jack
Use an Ohm meter to measure coil resistance [Figure 20-41-46]. Coil wires do not have polarity. Correct resistance for the auxiliary, lift and tilt lock…
Remove the mounting nut (Item 1) [Figure 20-41-42] from the solenoid cartridge. Installation: Tighten the mounting nut to 53 in.-lbs. (6 Nm) torque. Remove the…
Remove the lock valves (Item 1)[Figure 20-41-38], [Figure 20-41-39] & [Figure 20-41-40] from the BICS] valve. Installation: Tighten the lock valves to 25 ft.-lbs. (34…
Remove the check valve (Item 1)[Figure 20-41-35]. Installation: Tighten the valve to 20 ft.-lbs. (27 Nm) torque. Remove the O-rings (Item 1) and back-up ring…
Remove the fitting (Item 1) [Figure 20-41-32] from the valve. Using a flat blade screw driver, remove the lift arm by-pass orifice (Item 1) [Figure…
Remove the hydraulic control valve. (See BICSTM Valve, Removal And Installation on Page 20-41-9.) To remove the BICSTM from the control valve loosen and remove…
Remove the two screws (Item 1) [Figure 20-41-25] on the actuator retainer. Installation: Tighten the bolt and nut to 90-100 in.-lbs. (10,2-11,3 Nm) torque. Pull…