Remove the two bolts (Item 1) [Figure 60-130-30] from the foot sensor shield.
Installation: Tighten the bolts to 80 – 90 in.-lb. (9,0 – 10,2 Nโขm) torque.
Disconnect the foot lock solenoid connector (Item 1) [Figure 60-130-31] from the harness.
Remove foot lock solenoid (Item 2) [Figure 60-130-31].
Installation: Apply a drop of oil on the solenoid threads and tighten the solenoid to 35 – 40 ft.-lb. (47 – 54 Nโขm) lubed torque.
Check the O-ring (Item 1) [Figure 60-130-32] for damage. Replace as necessary.