BOBCAT S130 – FUEL SYSTEM – Fuel Shutoff Solenoid – Checking

Stop the engine and open the rear door [Figure 70-70-4].

Disconnect the connector (Item 1) [Figure 70-70-4] from the fuel shutoff solenoid.

Use an ohmmeter to check the fuel shutoff solenoid.

The reading between electrical connector terminal C and terminal A must be between approximately 15.6 ohm [Figure 70-70-5].

The reading between electrical connector terminal C and terminal B must be between approximately 0.35-0.4 ohm.