Remove the tilt port relief/anti cavitation valve (Item 1) [Figure 20-41-38] from the base end of the tilt section. Replace the O-ring (Item 1) [Figure…
Author: Jack
Loosen the lift circuit port relief/anti cavitation valve (Item 1) [Figure 20-41-36]. Replace the O-ring (Item 1) [Figure 20-41-37] before installation. Installation: Lightly lubricate with…
At the back side of the control valve, remove the lift section anti-cavitation valve (Item 1) [Figure 20-41-33]. Always use new O-ring (Item 1) [Figure…
At the front side of the control valve locate the tilt section load check valve (Item 1) [Figure 20-41-31]. At the front side of the…
Remove the tubeline (Item 1) [Figure 20-41-27] from the control valve. Remove the fitting (Item 1) [Figure 20-41-28] from the check valve. Remove the lift…
Remove the control valve from the loader. Remove the two mount bolts (Item 1) [Figure 20-41-17] from the lift actuator. Installation: Tighten the mounting bolts…
Lift and block the loader. (See Procedure on Page 10-10-1.) Raise the lift arms and install an approved lift arm support device. (See Installing on…
The hydraulic control valve is located inside the main frame on the right hand side, below the operators cab. The hydraulic control valve [Figure 20-41-1]…
Remove the tubeline (Item 1) [Figure 20-40-118]. Remove the check valve fitting (Item 1) [Figure 20-40-119] from the hydraulic control valve. Installation: Lubricate the O-ring…