BobCat 753 – HYDRAULIC/HYDROSTATIC FILTER – Housing Removal And Installation

Stop the engine and open the rear door.

Disconnect the charge pressure sender connector (Item 1), temperature sender connector (Item 2) and differential
pressure switch connector (Item 3) [Figure 20-70-1] from the filter housing.

Disconnect the oil cooler tubeline (Item 1) [Figure 20-70-2] from the filter housing.

Disconnect the hose (Item 2) [Figure 20-70-2] from the filter housing outlet.

Remove the two mounting bolts (Item 1) [Figure 20-70-3] from the filter housing mounting bracket.

Installation: Tighten the mounting bolts to 190-240 ins.-lbs. (29,2-36,7 Nm) torque.

Remove the hydraulic filter housing (Item 1) [Figure 20-70-4] from the mounting brackets.

Installation: Tighten the mounting bolts to 375-400 ins.-lbs. (42,4-45,2 Nm) torque.

Remove the filter from the hydraulic filter housing.

Reverse the removal procedure to install the filter housing and filter.