The tool listed is necessary for the following procedure: MEL1420 – Carrier Seal Tool Remove the hydrostatic motor. (See Removal And Installation on Page 30-20-1.)…
Category: BobCat 753
Clean all parts with solvent and dry with compressed air. Put grease on O-rings. Lubricate parts with oil. Install the poppet (Item 1) and spring…
Drain the oil from the motor. Seal all open ports and clean the motor with solvent. Put a mark across the sections of the motor…
Raise the lift arms and install an approved lift arm support device. (See Installing Lift Arm Support Device on Page 10-20-1.) Lift and block the…
The functions of the replenishing valves are: 1. To give replacement fluid to the low pressure side of the hydrostatic circuit. Replacement fluid is needed…
Remove the male coupler (Item 1) [Figure 20-121-2] & [Figure 20-121-3]. Installation: Tighten the male coupler (Item 1) [Figure 20-121-2] & [Figure 20-121-3] to 59…
Disconnect the auxiliary tubelines (Item 1) and drain tubeline (Item 2) [Figure 20-121-1] from the coupler block. Remove the two mounting bolts (Item 3) [Figure…
Inspect cartridges, check valves, solenoid valves and sealing washers for contamination or damage. Wash all parts in clean solvent. Use air pressure for drying them.…
Use a test meter to measure coil resistance [Figure 20-120-9]. Coil wires do not have polarity. Correct resistance is 11 ยฑ 1 ohms. Replace the…