Remove the BICS valve assembly from the control valve. (See BICSTM Valve, Removal And Installation on Page 20-41-9.) Remove the restrictor (Item 1) [Figure 20-40-51]…
Category: BobCat 753
Use an Ohm meter to measure coil resistance [Figure 20-40-49]. Coil wires do not have polarity. Correct resistance for the auxiliary, lift and tilt lock…
BobCat 753 – HYDRAULIC CONTROL VALVE (FOOT CONTROL) – BICSTM Valve Solenoid Disassembly And Assembly
Remove the mounting nut (Item 1) [Figure 20-40-45] from the solenoid cartridge. Installation: Tighten the mounting nut to 53 in.-lbs. (6 Nm) torque. Remove the…
Remove the lock valves (Item 1) [Figure 20-40-41], [Figure 20-40-42] & [Figure 20-40-43] from the BICSTM valve. Installation: Tighten the lock valves to 25 ft.-lbs.…
Remove the check valve (Item 1) [Figure 20-40-38]. Installation: Tighten the valve to 20 ft.-lbs. (27 Nm) torque. Remove the O-rings (Item 1) and back-up…
Remove the fitting (Item 1) [Figure 20-40-35] from the valve. Using a flat blade screw driver, remove the lift arm by-pass orifice (Item 1) [Figure…
Remove the control valve. (See BICSTM Valve Removal And Installation on Page 20-40-10.) To remove the BICSTM from the control valve loosen and remove the…
Lift and block the loader. (See LIFTING AND BLOCKING THE LOADER on Page 10-10-1.) Raise the lift arms and install an approved lift arm support…
Lift and block the loader. (See LIFTING AND BLOCKING THE LOADER on Page 10-10-1.) Raise the lift arms and install an approved lift arm support…